Do you need to do a double glue down application of Quietwalk Plus? Or can you only glue the top side of Quietwalk Plus to engineered wood flooring (ie not glue Quietwalk Plus to concrete subfloor)?
QuietWalk Plus 100SF Roll
Adhesives and Underlayment
Status:
Open Jul 20, 2024 - 11:20 AM
1answer
Staff Answer
Jul 25, 2024 - 01:39 AM
If you FLOAT a floor over QuietWalk Plus, you do not need any glue at all. But if you want to use glue, then you would do a Double Glue Down. You glue QuietWalk Plus to the subfloor, then you glue the engineered wood to the QuietWalk Plus. Although this can be done, it is not necessarily the ideal application. Please call us if you want to discuss it further.
View More Product Details
QuietWalk Plus 100SF Roll
Zero VOC, floating floor underlayment with built-in sound and vapor barrier and no anti-microbials QuietWalk Plus underlayment improves a floor four ways: provides a patented system of moisture protection reducing mold and mildew smooths out little sub-floor imperfections quiets impact sound and flo...