Answer
Feb 22, 2023 - 02:18 AM
It will work with conditions. Per Forbo, they state that areas to receive material should be clean, fully enclosed, and weather tight. The permanent HVAC should be fully operational and controlled and set at a minimum temperature 65� F (18.3� C). If this is not possible, the areas should be acclimated and controlled by means of temporary HVAC to the service level conditions expected during occupancy. The temperature and humidity should range from 75� F � 10�F (23.9� C � 5.5� C) with a 50% � 10% ambient relative humidity. These conditions must be established at least seven days prior to beginning the installation, maintained during the installation, and continued for at least seven days following the installation. Then follow the regular installation instructions and, as long as those are all followed, the sheet glue-down goods work well, even if well after the installation you see changes to temp and humidity well beyond that installation range.